Hand Held Refractometer


Product Description

Hand Held Refractometers
 
The Hand Held Refractometers are specially designed for measuring the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. And they can also test for the proportion of the water-soluble solution. They can be easily used and they are competitive in price. You only need to drop some liquid on the prism and then make it towards to the sunlight. Then the reading of the concentration will appear. ATC means Automatic Temperature Compensation.
 
1. For Brix
Model Range Min.Div. Accuracy Remark
RHB0-80 Brix: 0-80% 0.5% ±0.5% No ATC
RHB0-90 Brix: 0-90% 0.5% ±0.5% No ATC
RHB-90S 0~42, 42~71, 71~90% 0.2% ±0.2% ATC
RHB-10ATC Brix: 0-10% 0.1% ±0.10% ATC
RHB-18ATC Brix: 0-18% 0.1% ±0.10% ATC
RHB-20ATC Brix: 0-20% 0.1% ±0.10%  ATC
RHB-32ATC Brix: 0-32% 0.2% ±0.20% ATC
RHB-50ATC Brix: 0-50% 0.5% ±0.50% ATC
RHB-62ATC Brix: 28-62% 0.2%x ±0.2% ATC
RHB-82ATC Brix: 45-82% 0.5% ±0.5% ATC

2. Beer Refractometer 
Model Rang  Min.Div. Accuracy
AMR008 Brix: 0~32% 0.2% ±0.2%
SG: 1.000~1.120 0.001 ±0.001

3. Salinity Refractometer
Model Range Min.Div. Accuracy Remark
RHSA-4ATC  Salinity: 0-40‰ Salinity: 1‰ Salinity:±1‰ ATC
Gravity: 1.000-1.030  Specific gravity: 0.001 Specific gravity: ±0.001
RHS-10ATC Salinity: 0-100‰ Salinity: 1‰ Salinity: ±0.001 ATC
Gravity: 1.000-1.070  Gravity: 0.001 Specific gravity: ±0.001 
RHS-10BATC Brix: 0-10% Brix: 0.2% Brix: ±0.2% ATC
Salinity: 0-100‰ Salinity: 1‰ Salinity: ±1‰
Gravity: 1.000-1.070 Gravity: 0.001 Specific gravity: ±0.001
RHS-28ATC Salinity: 0-28% Salinity: 0.2% Salinity: ±0.2% ATC
RHS-28BATC Salinity: 0-28% Salinity:0.2% Salinity: ±0.2% ATC
Brix: 0-32% Brix:0.2% Brix: ±0.2%
RHS-35ATC Salinity: 0-35% Salinity: 0.5% Salinity: ±0.5% ATC
Note: RHSA-4ATC popular for aquarium; RHS-35ATC popular for food indstry. 

4. Clinical Protein Refractometer
Model Range Min.Div. Accuracy
VUR1T Serum Protein: 0-12g/dl Serum Protein:0.2g/dl Serum Protein:±0.2g/dl
Urine Gravity: 1.000-1.040sg Specific Gravity:0.002sg Specific Gravity:±0.002sg 
VUR2T Serum Protein: 0-12g/dl Serum Protein:0.2g/dl Serum Protein:±0.2g/dl 
Urine Gravity: 1.000-1.050sg Specific Gravity:0.002sg Specific Gravity:±0.002sg
Refractive Index:1.3330-1.3600RI Refractive Index: 0.0005RI Refractive Index:±0.0005
VUR3T Serum Protein: 0-12g/ml Serum Protein:0.2g/ml Serum Protein:±0.2g/ml
Urine Gravity: 1.000-1.050UG Specific Gravity:0.005UG Specific Gravity:±0.002UG
Refractive Index:1.3330-1.3600nD Refractive Index: 0.0005nD Refractive Index:±0.0005nD
VUR4T Serum Protein: 0-12g/dl Serum Protein:0.2g/dl Serum Protein:±0.2g/dl
Urine Gravity: 1.000-1.040UG Specific Gravity:0.005UG Specific Gravity:±0.002sg
Refractive Index:1.3330-1.3600nD Refractive Index: 0.0005nD Refractive Index:±0.0005nD 

5. PET (CAT, DOG) Clinical Protein Refractometer
Model Rang  Min.Div. Accuracy
AMR016 Serum Protein/Plasma: 2-14gms/100ml 0.1 ±0.1g/dl
Cat Urine Gravity: 1.000-1.060 0.001 ±0.001sg
Dog Urine Gravity: 1.000-1.060
 
6. Automotive AdBlue / DEF Urea Concentration Test Meter  
Model Range Min. Div. Remark
AMR001 Urea: 0-40%

0.2%

ATC, Urea 32.5%
AMR002 Urea: 0-40% 0.2% ATC
EG: -60°F ~ 32°F 10°F
PG: -50°F ~ 0°F 10°F
AMR003 Urea: 0-40% 0.2%
EG: -50°C ~ 0°C 5°C
PG: -50°C ~ 0°C 5°C
CW: -40°C ~ 0°C 10°C
AMR004 Urea: 30-35% 0.2%
EG: -50°C ~ 0°C 5°C
PG: -50°C ~ 0°C 5°C
CW: -40°C ~ 0°C 10°C
BF: 1.10 ~ 1.40Kg/L 0.01Kg/L

7. Milk Refractometer
Model Range Min. Div. Remark
AMR005 Soybean Milk: 0-25% 0.5% No ATC
Brix: 0-32% 0.2%
AMR006 Water in Milk: 0-20% 0.2% No ATC

8. Battery/Antifreeze/Cleaning Fluid Refractometer
RHA-100ATC
Ethylene Glycol: -84° F-32°F
Propylene Glycol:-60° F-32°F
Battery: 1.100-1.400sg
Ethylene Glycol: 5°F
Propylene Glycol: 5°F
Battery: 0.01sg
Ethylene Glycol: ±5° F
Propylene Glycol: ±5° F
Battery: ±0.01sg
ATC
RHA-200ATC
Ethylene Glycol:-60°C-0°C
Propylene Glycol:-50°C-0°C
Battery: 1.100-1.400sg
Ethylene Glycol:5°C
Propylene Glycol:5°C
Battery:0.01sg
Ethylene Glycol:±5°C
Propylene Glycol:±5°C
Battery:±0.01sg
ATC
RHA-503C
Battery: 1.100-1.400sg
Ethylene Glycol: -50°C-0°C
Propylene Glycol: -50°C-0°C
Cleaner: -40°C-0°C
Battery: 0.01sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Cleaner: 5°C
Battery: ±0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Cleaner: ±5°C
ATC
RHA-800ATC
B:1.000~1.400sg
A:0%~100%
F:-60°C~0°C
0.01sg
5%
5°C
±0.01sg
±5%
±5°C
ATC

9.  Brake Fluid Checker
Model Range Min.Div. Remark
VBK1
DOT3: 1-6% Moisture
          Boiling Point: 250-500°F 
Super DOT3: 1-6% Moisture
          Boiling Point: 250-570°F
1% ATC
VBK2
DOT3: 1-6% Moisture
          Boiling Point: 125-275°C 
Super DOT3: 1-6% Moisture
          Boiling Point: 150-275°C
1% ATC

10. Alcohol Refractometer 
Model Range Min.Div. Accuracy
RHW-80 w/w: 0-50%, 50-80% 0-50%: 1%; 50-80%: 2.5% ±1%
RHW-25ATC 0-25% VOL; Brix: 0-40% 0.2% ±0.2%

11. Refractive Index
Model Range Min.Div. Accuracy
VND1 nD.1.333-1.520 0.001 ±0.002 ATC
VND2 nD.1.333-1.380 0.001 ±0.002 ATC
VND4 nD.1.435-1.520 0.001 ±0.002 ATC

12. Bee Honey Refractometer
Model Range Min.Div. Accuracy
RHH13-25 water: 13-25% water:0.1% water:±0.1%
RHH12-30 water: 12-30% water:0.1% water:±0.1%
RHH-92ATC
Brix: 58-92%
Baume: 38-43Be'
water: 12-27%
rix: 0.5%
Baume: 0.5Be'
water: 1%
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%
RHH-90ATC
Brix: 58-90%
Baume: 38-43Be'
water: 12-27%
Brix: 0.5%
Baume: 0.5Be'
water: 1%
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%

13. Wine Refactometer
Model Range Min.Div. Accuracy Remark
RHW-25aATC
Alcohol:0-25%VOL
Baume: 0-20Baume 
Alcohol:0.2% 
Baume: 0.2 be°
Alcohol:±0.2% 
Baume: ±0.2 be°
ATC
RHW-25ATC Alcohol:0-25% Alcohol:0.2% Alcohol:±0.20% ATC
RHW-25bATC
Alcohol:0-25%VOL 
Brix: 0-40%
Alcohol:0.2% 
Brix: 0.2%
Alcohol:±0.2% 
Brix: ±0.2%
ATC
RHBS-32aATC
Brix: 0-32%
Oechsle: 30-140°Oe
Brix: 0.2%
Oechsle: 1.0°Oe
Brix: ±0.2%
Oechsle: ±1.0°Oe
ATC
RHBS-32ATC
Brix: 0-32%Mas Sacch
Oechsle: 0-140°Oe
KMW: 0-27°(Babo)
Brix: 0.2%
Oechsle: 1.0°Oe
KMW: 0.2°
Brix: ±0.2%
Oechsle: ±1.0°Oe
KMW: ±0.2°
ATC
RHBS-44ATC
Brix: 0-44%
Oechsle: 0-190°Oe
KMW: 0-38°(Babo)
Brix: 0.4%
Oechsle: 2.0°Oe
KMW: 0.4°
Brix: ±0.4%
Oechsle: ±2.0°Oe
KMW: ±0.4°
ATC

14. Emulsion Reractometer
Model Range Min.Div. Accuracy
AMR011 M10: 0~15% 0.5% ±0.5%
MDT: 0-15%

15. Contact Lens Refractometer
Model Range Min.Div. Accuracy
AMR012 35~80% 1% ±1%

16. IPA (Iso-Propyl Alcohol)  Refractometer
Model Range Min.Div. Accuracy
AMR015 0~60% (v/v) 1% ±1%
-23°C~0°C 1°C ±1°C